Mechanical Reinforcing Bar Anchorages shall be the cold-swaged taper-threaded coupler type, which shall be assembled with 5As or 10As Heads

Dimensiones y referencias del producto

  

 

 

 

Aplicaciones

Replaces hook bars in beam-column joints, knee joints, pile caps and column roof slab connections. Replaces stirrup bars as confinement steel.

Características

• ACI 318 MECHANICAL ANCHORAGE - In accordance with section 12.6, BPI Barsplicer DoughNUTs develop at least the strength of the bar, fy Grade 60. In air tests exceed 1.25 fy Gr.60..
• HEAD VERSUS HOOK - while hook bars reduce development length compared to straight, they might bring about congestion. Doughnut's alleviate this problem and facilitate bar placement.
• HEAD AREA - 5Ab full cross-sectional area with at least 4Ab projected bearing area in tension (Ab = area of reinforcement). Minimum recommended anchorage length = 12 db** (db = bar dia)/
**Ref: "headed Reinforcement A Viable Option" John W. Wallace.

Ventajas

Preinstalled on Grade 60 by means of standard threads - saves field labor. Easy placement - no special bend directions, minimal detailing, saves space, more design flexibility.

Función

Reduces development length of bars by transmitting a proportion of force from bar to bar to concrete via head bearing area.

Galería fotográfica
  • general2.jpg
  • imagen.jpg
  • imagen2.jpg
Instalación

In-situ installation- although normally pre-Installed, components can be swaged to existing Bars, if needed; using BPI-Grip field presses.

Instalación imágenes


Este sitio web utiliza cookies propias para recopilar información con la finalidad de mejorar nuestros servicios. Si continua navegando, supone la aceptación de la instalación de las mismas. El usuario tiene la posibilidad de configurar su navegador pudiendo, si así lo desea, impedir que sean instaladas en su disco duro, aunque deberá tener en cuenta que dicha acción podrá ocasionar dificultades de navegación de la pagina web.